Metrax defibrillators




HeartSave - A reliable life-saver
The PRIMEDIC HeartSave is a mobile defibrillator, which relieves you of grave decisions:
The devices performs an automatic ECG analysis within 12 seconds and decides whether a defibrillation is necessary. Then a touch of a button is sufficient to trigger the life-saving electric pulse that eliminates the ventricular fibrillation. Thus valuable seconds and minutes are used to save life.


Features of the PRIMEDIC AED HeartSave Series:

  • Dynamic and individual adjustement of the biphasic shock by measurement of the patient impedance (continously variable between 140 - 360 J, according to the ERC directives 2005/2006)
  • The impulse length is always 15 ms, independent from patient (this enables complete polarisation of the myocard).
  • Current controlled biphasic impulse (positive and negative constant at 20 Ampere; according to the ERC directives) detectable conservative for the myocard.
  • 3 languages (Basic version: German, English, Spanish languages are currently available; updates by installed or removable CFCard
  • IP55 (water-jet protected and dustproof)
  • Power supply by 5 year lifetime battery, accumulator or mains supply circuit
  • Fast data transfer by installed Compact Flash Card for storage of up to 48 hours for ECG, up to 5,4 hours for text and ECG and for updates f.e. text or firmware as comparison find here the transfer rates of usual interfaces of manufacturers:
    • CF-Card app. 3,5 MB/s up to max. 12 MB/s
    • USB 1.1 app. 1500 kbit/s
    • Bluetooth app. 434 kbit/s max. 723kbit/s
    • Serial Interface (RS232) app. 128 kbit/s
    • Infrared app. 1,152 Mbit/s but limited by RS232
  • Navigation approval (salt fog tested), Railroad aproval (12,66 Hz, Helicopter approval up to 4000m over ground and flight capability, (Rally sport tested)
  • Single push button operation of the layperson device. Automatic switch ON when the device is opened, manual switch ON/OFF additionally possible
    Analysis-/ Datatransfer-Software is contained within every device (no extra costs)
  • AED and AED-M are available with different telemetry modules (I and II) Module I with GSM to defined receipient and automatic alarm when sending a SMS, module II with extra ECG transfer in realtime mode
  • HearSave AED monitor devices are with high resolution 4,7 Blue-Mode Monitor (12cm diagonal and currently largest display of all AEDs)
  • When using a monitor equipped device there is a possibility for ECG monitoring by use of a separate ECG cable and standard disposable ECG electrodes
  • Automatic synchronisation at AED HeartSave6 & 6s in manual mode
  • SpO2 Sensor at AED HeartSave6s for measurement of the oxygen saturation
  • All devices are upgradable and are, concerning holder, electrodes and powersupply, compatible to the professional devices of the PRIMEDIC XD series.





HeartSave AED

HeartSave AED-M

HeartSave 6

HeartSave 6S



Technical Data:
HeartSave AEDHeartSave AED-MHeartSave 6HeartSave 6S
Defibrillation
Wave formbiphasic current controlled pulsebiphasic current controlled pulsebiphasic current controlled pulsebiphasic current controlled pulse
Energy140 – 360 J140 – 360 J140 – 360 J140 – 360 J
Charging time<12 sec<12 sec<12 sec<12 sec
Operating modesasynchronousasynchronousasynchronous
AUTO-SYNC
asynchronous
AUTO-SYNC
ECG
LeadIIIII, II, III, aVr, aVf, aVII, II, III, aVr, aVf, aVI
Patient's impedance range20 - 200 Ohm20 - 200 Ohm20 - 200 Ohm20 - 200 Ohm
Heart rate30 - 300 per min30 - 300 per min30 - 300 per min30 - 300 per min
Alarmsnot available/no30 - 300 per min30 - 300 per min30 - 300 per min
VF/VT detection
Manual overrideavailable/yesavailable/yesavailable/yesavailable/yes
Analysis timenot available/nonot available/no7 – 12 sec7 – 12 sec
VF threshold0,2 mV0,2 mV0,2 mV0,2 mV
Asystole threshold<0,2 mV<0,2 mV<0,2 mV<0,2 mV
Artefact detectionavailable/yesavailable/yesavailable/yesavailable/yes
Pacemaker detectionavailable/yesavailable/yesavailable/yesavailable/yes
Pulse oxymeter
Typenot available/nonot available/nonot available/noNellcor
Indication areanot available/nonot available/nonot available/no100 ... 0%
Calibration areanot available/nonot available/nonot available/no100 ... 50%
LCD monitor
Typenot available/noLCD, blue-modeLCD, blue-modeLCD, blue-mode
Dimensionsnot available/no95 x 72 mm95 x 72 mm95 x 72 mm
Resolutionnot available/no320 x 240 (Pixel size 0,36 x 0,36 mm)320 x 240 (Pixel size 0,36 x 0,36 mm)320 x 240 (Pixel size 0,36 x 0,36 mm)
Storage battery status displaynot available/noavailable/yesavailable/yesavailable/yes
Speednot available/no25 mm/s25 mm/s25 mm/s
Patient informationnot available/noHeart rate, number of defibrillations, number of detected VF/VT, total resuscitation timeHeart rate, number of defibrillations, number of detected VF/VT, total resuscitation timeHeart rate, number of defibrillations, number of detected VF/VT, total resuscitation time
Electrodes
Non-polarized electrodesavailable/yesavailable/yesavailable/yesavailable/yes
Storage3 years3 years3 years3 years
Cable length1,5 m1,5 m1,5 m1,5 m
Data backup
Internal memory8 MB RAM8 MB RAM8 MB RAM8 MB RAM
Removable memory16 - 128 MB or 1 - 5,4 h with voice recording or 6 - 48 h without voice recording16 - 128 MB or 1 - 5,4 h with voice recording or 6 - 48 h without voice recording16 - 128 MB or 1 - 5,4 h with voice recording or 6 - 48 h without voice recording16 - 128 MB or 1 - 5,4 h with voice recording or 6 - 48 h without voice recording
Voice recordingavailable/yesavailable/yesavailable/yesavailable/yes
Software EmergencyECG-Viewer (optional)ECG-Viewer (optional)ECG-Viewer (optional)ECG-Viewer (optional)
Battery
TypeLiMnO2LiMnO2LiMnO2LiMnO2
Storage5 years5 years5 years5 years
Discharges110110110110
Monitoring15 h15 h15 h15 h
Voltage16 V16 V16 V16 V
AkuPak
TypeNiCdNiCdNiCdNiCd
Discharges56565656
Monitoring6 h6 h6 h6 h
Voltage10,6 V10,6 V10,6 V10,6 V
Charging timeabout 1 habout 1 habout 1 habout 1 h
PowerLine
Voltage90 - 264 V90 - 264 V90 - 264 V90 - 264 V
Frequency50/60 Hz50/60 Hz50/60 Hz50/60 Hz
Environmental conditions
Operation conditions0° - 55°C0° - 55°C0° - 55°C0° - 55°C
Storing conditions-30° - +65°C-30° - +65°C-30° - +65°C-30° - +65°C
Regulatory
AHA, ERC protocolavailable/yesavailable/yesavailable/yesavailable/yes
Protection type IP 55available/yesavailable/yesavailable/yesavailable/yes
Dimensions
Height x width x depthabout 26 x 26 x 9,0 cmabout 26 x 26 x 9,0 cmabout 26 x 26 x 9,0 cmabout 26 x 26 x 9,0 cm
Weight without power supply unitabout 1,8 kgabout 2,0 kgabout 2,0 kgabout 2,2 kg
Weight with power supply unitabout 2,3 kgabout 2,5 kgabout 2,5 kgabout 2,7 kg




Brochures,Manual, Demo-Software

     
     
 
 